The same patient, despite the best efforts of the anaesthetist, has not been successfully intubated after three attempts at laryngoscopy. Which of the following statements are correct?
Select one or more options from the answers below.
Correct.
Not quite right.
Incorrect.
Score: out of
Retry
A. False. Plan B is not appropriate in this scenario.
B. True. Oxygenation is the priority.
C. False. An LMA should be inserted next, reducing the cricoid pressure during insertion.
D. True. This is a balance of risks. However, if the patient is relatively stable, it is in their interest to wake them up and perform an awake fibre-optic intubation.
E. True.
Refer to resources to view the algorithms - Scenario 2 Plan C and Scenario 3 Plan D.