Use airway positioning and adjuncts to maintain a clear airway
before LMA insertion
Ensure adequate depth of anaesthesia (including opioids) before
instrumenting the airway
Use correct technique for LMA placement
Check the quality of the airway (manual ventilation and spontaneous
ventilation) prior to allowing surgery to start. Do not accept a
partially obstructed airway